industrial hygiene Archives - 鶹TVվ /tag/industrial-hygiene/ Tue, 20 Jan 2026 20:01:06 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 Understanding and Managing Your Risk to Legionella /understanding-and-managing-your-risk-to-legionella/ Tue, 20 Jan 2026 18:28:29 +0000 /?p=247236 The post Understanding and Managing Your Risk to Legionella appeared first on 鶹TVվ.

]]>

Q&A with Alex Peck, 鶹TVվ National Director of Industrial Hygiene & Building Science

What isLegionella,and why is it dangerous?

In 1976,one of the topnewsstories was themysterious pneumoniaoutbreak at the landmark Bellevue-Stratford Hotel in Philadelphia, Pennsylvania.

Approximately 4,000 representatives from the stateAmerican Legion metfor a bicentennial conventionat the hotelthatJuly.The meeting went off without any issues, but several daysfollowing the event,hundreds ofattendeesbegan coming down with pneumonia-like symptoms.By August,approximately30 people haddiedfrom complications. Following the outbreak, a research microbiologist fromthe Center forDiseaseControl and Prevention (CDC) determined the cause to be anewbacterium, known today asLegionellapneumophilia, which is commonlyfound in water pipes and air conditioning units.

This first outbreakidentifiedapublic healththreatforlarge facilities like hotelsand hospitals, where watermoves slowly through a complex web of pipes, valves and other plumbing fixtures, and the threat is still veryreal today.Yearly outbreaks ofLegionnaire’s diseaseand Pontiac fever(a milder case oflegionellosis)occur,including recent casesinCalifornia,New Yorkand Florida.

While the threat is realand likely increasingdue to a combination of increased surveillance, aging populations, increased urban densityandwarmer temperaturesthat create a prime environment for increased bacteria growth(especially inAmerica’sagingbuildings and their watersystems), it is imperative for businesses to focus on prevention, rather than mitigation.Not only is prevention less costly,but itcanmost importantly helpsave livesandprotect yourcompany’s reputation.Not to mention, outbreaks can lead to extended closures and loss of business, which can be costly too.

Is Legionnaire’sdisease preventable?

Yes, Legionnaire’s disease is preventable if businesses take proper precautions tomaintaintheir water systems.The CDC reported 6,000 cases in 2015and predicts annual cases range from 10,000 to 15,000.

How can your business protect itself fromlegionella outbreaks in your facilities?

Legionellaoutbreaks are likely to occur in buildings withlarge,complex water systems, such as hospitals, nursing homes,hotels, office buildings,manufacturingfacilitiesand inengineered water systems like cooling towers, waterfountainsand hot tubs.

The mostcommonplacesto breed bacterial growth include:

  • Cooling towers.
  • Water features (falls, foundations, ponds, misters).
  • Swimming pools and hot tubs.
  • Drinking water fountains.
  • Aging water systems.
  • Unused plumbing.
  • Ice machines.
  • Water heating and hot water distribution.
  • Shower heads and faucets.

However, by conducting formal evaluations toidentifyplaceswhereLegionellagrowthis likely to occur in your facility, you can proactively mitigate your risk by taking a basic approachthat involves:

  • Creatinga team.
  • Diagramingwater systems.
  • Evaluatingsystems for risks.
  • Implementingcontrols.
  • Monitoringcorrective actions.
  • Assessingprogram effectiveness.
  • Documentation.

How is Legionella regulated?

Unfortunately,notmanyregulations specific toLegionella(although the number is increasing)exist, and currently no federal regulationsare in place.TheCenters for Medicare and MedicaidServices (CMS)has issued amemothat requiresall Medicaid facilitiesnationallyto develop andmaintainaLegionellamanagement program,in accordance withtheCDC recommendations.

Some state agencies have adopted their ownLegionellaregulations.For instance, in 2015 and 2016, New York published rules for cooling towers and medical facilities, whichinclude registration of cooling towers, monitoring, notification,maintenanceand reporting.

More recently,New Jerseypassedacomprehensiverule,requiringcommunity water systems toalwaysmaintaina minimum detectable disinfectantlevel inall active parts ofitspublic water system.Thislawalsorequires owners or operators of covered buildings or facilities (including hospitals, certain health care facilities,prisonsand certain senior housing facilities) to develop a water management program to minimize the growth of L𲵾DzԱ bacteria in the facility’s water system and to include periodic sampling and testing for the presence of bacteria. It also includes fines for non-compliance.While some state regulations exist, more can be done to protect public health.

What is 鶹TVվ’ Experience in Addressing Legionella?

鶹TVվ’ team of highly qualifiedindustrial hygiene and building science experts have worked with businessesand organizationsfor many years to mitigate the potential risk ofLegionella.Our teamhelps bycreatingwater management plans,as well asconductingsamplingto identifyLegionellaand makerecommendations to helpmitigateanyissues.

鶹TVվ recently helped a25-storyoffice building by performing initial water sampling.WeidentifiedLegionellain one of the kitchen sinks. Our team helpedthe client remediate the issue until theLegionellabacteria weregone.

We have many case studies like this; however,to understand the real risks,weconsiderseveral factors.This might includethe number and age ofwater and plumbingfixtures, as well as how the systems have been maintained.For example, a hotel has moreriskthan an office, and an old hotelis more likely to haveconditions favoringLegionellagrowththan a newly constructed hotel. Also, occupants of a retirement community are more likely to be susceptible toLegionellosis disease than the occupants of a high school.

If you are curious as to whether your business might be at risk for aLegionellaoutbreak, justremember,ifa building hasawater system, there is a risk forLegionellagrowth. While there arenumerousfactors at play, the key to preventingLegionellagrowth ismaintainingproper water quality,disinfectionresiduals, temperatures and flow-through—all pieces of an effective water management program.

Brett Haggerty

Alex Peck, CIH, MBA

National Director of Industrial Hygiene and Building Science

Alex Peckserves as鶹TVվ’ National Director of Industrial Hygiene and Building Science, responsible fordelivering industrial hygiene and safety to a variety of client groups, including heavy industry, mining companies, oil companies, railroads, manufacturing, military, government agencies, construction companies, insurance companies, schools,attorneysand healthcare providers. He bringsnearly23years of experience to his role as an industrial hygienistexpert, with specialemphasis on health and safety program development and implementation.

The post Understanding and Managing Your Risk to Legionella appeared first on 鶹TVվ.

]]>
Stagnant Water Issues in Buildings /stagnant-water-issues-in-buildings/ Wed, 02 Mar 2022 00:04:07 +0000 /?p=243152 The post Stagnant Water Issues in Buildings appeared first on 鶹TVվ.

]]>

Author: Jack Springston, CIH, CSP, FAIHA,
Industrial Hygiene Services Manager and Training Director at 鶹TVվ

Building water systems are critical and necessary to all building operations. As schools begin to reopen, and companies and employees return to the workplace, employers must take steps to ensure that the water in their buildings is safe for occupants. The potential for lead to leach into water can increase the longer the water remains in contact with lead in plumbing. As a result, buildings that have remained essentially closed for months due to the COVID-19 pandemic, and those with intermittent water use patterns, such as schools, may have elevated lead concentrations.

Additionally, water that sits stagnant for an extended time in water mains, premise plumbing, and water heaters loses residual chlorine disinfectant, leading to an increased risk of bacterial colonization, including Legionella. Building operators cannot assume that municipal water suppliers effectively disinfect and flush the lines, or address bacterial growth that occurs in the building’s plumbing. The standard of care for managing waterborne pathogens has shifted to building owners and operators. After reoccupying buildings that have been largely closed and unoccupied for weeks and months, the risk of suffering an outbreak of Legionnaires’ disease is very real. It falls upon the owners and operators to assess and manage these risks, and implement preventative and remedial measures, if needed.

Water testing for lead and Legionella bacteria helps evaluate plumbing systems and outlets so that, if necessary, targeted remediation efforts can be taken. Such testing is a key step in understanding if there is a problem and, if so, in designing an appropriate response.

WHAT IS FLUSHING?
Simply put, “flushing” involves turning on faucets and opening taps to flush out the stagnant water that has been standing in the building’s pipes and outlets and replace it with “fresh” water. The flushing time can vary by the type of outlet being cleared, as well as how far away the outlet is from the water main entering the building. The degree to which flushing can reduce lead levels will vary depending upon the age and condition of the plumbing, as well as the corrosiveness (i.e., pH) of the water. Similarly, the degree to which flushing can lower and control bacteria and biofilms depends on the type and levels of disinfectant in the supply water to the building. Flushing can be an effective tool to control lead and waterborne pathogens exposures, but only when used appropriately.

FLUSHING TO IMPROVE WATER QUALITY
In schools, office buildings, and other facilities, establishing a periodic, ongoing flushing program is one of the easiest ways to ensure that the water quality in the building is preserved by decreasing water age. Flushing does not require installation or maintenance of supplemental water treatment equipment, and the associated costs. Flushing should be used as a regular practice to ensure the water is regularly replaced in the system and residual disinfectant levels are sufficient to control microbial growth.

FLUSHING AND SAMPLING FOR LEAD
When sampling for lead, it is important that the sample is representative of the water that is being consumed. For this reason, the U.S. Environmental Protection Agency (EPA) does not recommend that schools collect samples first thing in the morning after weekends, holidays, or vacations/breaks because the water will have remained stagnant for too long and would not be typical of the water used for drinking during the normal school day. Accordingly, drinking water outlets should be flushed after such breaks to maintain water quality.

The EPA does not recommend flushing for the sole purpose of sampling, but rather as a regular standard practice to ensure the building water does not stagnate. Flushing outlets immediately before sampling may lead to lead results that are lower than the actual representative levels in the water. Flushing is only appropriate when conducting follow-up flush sampling or sequential sampling to identify potential lead concerns in the interior plumbing.

FLUSHING AND SAMPLING FOR LEGIONELLA
When performing routine sampling for Legionella, first draw samples are preferred and represents the water conditions at the tap and the immediate piping. Use flush samples for monitoring water sources, such as storage tanks (cold or hot) and centralized or non-centralize hot water heaters. A flush water sample represents the water conditions in the piping upstream of the tap, in the riser, in a circulated loop, or in a pipe header.

FLUSHING AND REMEDIATION FOR LEAD
Routine flushing can be a quick and easy solution to elevated lead levels, especially when contamination is localized in a certain area of the building or in a small building. Flushing can be used as a short-term solution, while solutions that are more permanent are being developed and implemented.

An important consideration when utilizing flushing for remediation is the frequency that flushing needs to occur (e.g., daily, twice weekly, etc.), the labor requirements to perform such flushing, and whether it is even feasible to do at your particular facility. Depending upon the age and condition of the plumbing, and the corrosiveness of the water, elevated lead levels can return relatively quickly following flushing. Unless you can ensure lead levels remain low throughout the day, it is not recommended to flush only once a day or once a week as a solution to high lead levels. Flushing for one or two minutes, immediately prior to use, may be a short-term solution, in conjunction with signage and schedules.

Make sure to periodically collect samples after implementing a flushing-for-remediation program to verify that the water being provided does not contain elevated lead levels.

FLUSHING AND REMEDIATION FOR LEGIONELLA
While routine flushing can help to ensure that residual disinfectant levels are maintained within the plumbing system, to help control bacteria growth, such flushing is typically inadequate to remediate a system once it has become contaminated. Building water control strategies for waterborne pathogens, such as Legionella, should include routine water sampling for culturable Legionella, routine flushing and water sampling for free residual disinfectant levels and water temperature, and periodic cleaning and disinfecting of aerator devices and shower heads.

THE DOS AND DON’TS OF FLUSHING

Do:

  • Utilize routine flushing as a way to improve overall water quality in the building.
  • Flush when it is included in a sample instruction (e.g., collecting a follow-up flush sample).
  • Thoroughly flush after doing any plumbing work or remediation (e.g., removing and replacing lead containing plumbing or fixtures). Flushing can help clear out debris or lead particulates that may be released when such work is performed.

ٴDz’t:

  • Flush right before sampling. Flushing prior to sampling may cause samples to not be representative of actual lead or Legionella concentrations that initially come out of the tap.
  • Flush to reduce lead levels in water coolers/fountains. Flushing is not recommended as a practical remedy for these devices.
  • Flush as a sole remediation method after finding unacceptable lead levels in your water, without ensuring that lead levels will remain low throughout the day.
  • Use flushing alone as a long-term remediation method. Flushing can be used as a short-term measure, paired with a permanent remediation, such as removal and replacement or disinfection.

 

TIPS FOR DEVELOPING A FLUSHING PLAN
When developing a flushing program as a regular practice, or as a short-term remediation effort for lead:

  • Determine how and where the municipal water enters the building and flows through your facility, and create a flow diagram;
  • Locate all water outlets that are used for consumption purposes or where aerosols may be generated and released into the air;
  • Utilize signage to indicate when, and for how long, flushing needs to occur at each outlet;
  • Create a water management program team to develop, implement, and document the program, and
  • Develop a testing program to verify and validate the effectiveness of any control measures put into place.

The post Stagnant Water Issues in Buildings appeared first on 鶹TVվ.

]]>